Your spray valve probably isn't broken. It's got scale.
Before you order anything: the large majority of "this pre-rinse is dying" cases are
mineral deposits on the spray face. Try this first. It's free, it takes twenty minutes,
and you already own everything you need.
Symptoms
What scale actually looks like
It rarely announces itself as a failure. It creeps in over weeks, which is why crews usually blame
the valve instead of the water.
Pressure drop that developed gradually, not overnight
An uneven or split fan — one side sprays fine, the other dribbles
The stream angles off instead of going where you point it
Individual holes blocked and visible white or grey crust on the face
Nothing changed — no new faucet, no plumbing work, no drop in building pressure
A useful distinction: if the pressure died suddenly across every fixture in the building, you have
a supply problem, not a scale problem. Scale arrives slowly, and it arrives only at the nozzle.
The face unscrews from the body — that is what makes the vinegar soak possible.
The 20-minute soak
Close the supply stop under the sink.
Unscrew the spray face. On most heads this is hand-tight only — no tools. If it won't budge,
grip it with a cloth for purchase, not with pliers directly on the chrome.
Drop it into white vinegar. Plain household white vinegar. Undiluted. You only need enough
to cover the face.
Wait 20 minutes. Resist the urge to scrub early — soaking does most of the work.
Brush gently with a soft brush. An old toothbrush is ideal. Push a pin through any hole
that's still blocked, working from the back so you don't deform it.
Rinse it out and screw it back on. Hand-tight is enough. Don't crank it.
Open the supply slowly and check for a clean, even fan.
Dark openings are blocked. A ragged or lopsided fan is usually this.
Don't reach for anything stronger than vinegar. Harsh descalers can attack finishes and seals,
and they aren't necessary for calcium. If vinegar doesn't shift it after two rounds, move on rather
than escalating chemicals.
If the soak didn't work
Two rounds twenty minutes apart handles most cases. If it comes back clean and still sprays badly,
you're dealing with one of these:
Same decision; usually the point where replacement wins
Hose cracked, kinked, or leaking
Hose is the most stressed part of the assembly
Replace the hose itself
Stop doing this every month
Prevention is honestly just repetition.
Once a month: pull the face and give it a five-minute vinegar bath during close-down.
Waiting for symptoms means waiting until it's already slowing down service.
Hard water areas: every two weeks. Ask around — your ice machine filter life tells you
roughly where your water sits.
Print this page and tape it up by the dish machine. Half the value is making sure the
night crew doesn't bin a valve that needed twenty minutes in vinegar.
The expensive version of this mistake: commercial kitchens replace spray heads all the time
that were never broken. The unit goes in the bin, someone orders a new one, and the new one scales
up in exactly the same way in about the same number of weeks. Unless you change the maintenance, you
change nothing.
Still needs replacing?
If you've ruled out scale and the unit genuinely needs replacing, check the thread first so it
arrives right the first time: read the fit guide. Then decide
whether you want to rebuild or replace outright —
that cost comparison is here.